{
  "type": [
    "DigitalFacilityRecord",
    "VerifiableCredential"
  ],
  "@context": [
    "https://www.w3.org/ns/credentials/v2",
    "https://vocabulary.uncefact.org/untp/0.7.0/context/"
  ],
  "id": "https://credentials.sample-refinery.example.com/dfr/smelter-002",
  "issuer": {
    "type": [
      "CredentialIssuer"
    ],
    "id": "did:web:sample-refinery.example.com",
    "name": "Sample Copper Refinery Co. Ltd",
    "issuerAlsoKnownAs": [
      {
        "type": [
          "Party"
        ],
        "id": "https://www.sample-register.example.com/henkorireki-johoto.html?selHouzinNo=REF-001",
        "name": "Sample Copper Refinery Co. Ltd",
        "registeredId": "REF-001",
        "idScheme": {
          "type": [
            "IdentifierScheme"
          ],
          "id": "https://www.sample-register.example.com",
          "name": "Japan Corporate Number (Houjin Bangou)"
        }
      }
    ]
  },
  "validFrom": "2025-01-15T00:00:00Z",
  "validUntil": "2028-01-15T00:00:00Z",
  "name": "Digital Facility Record — Sample Copper Refinery",
  "credentialSubject": {
    "type": [
      "Facility"
    ],
    "id": "https://facility-register.example.com/fac-002",
    "name": "Sample Copper Refinery",
    "description": "Copper smelting and electrolytic refining facility in Sample, Oita Prefecture, Japan. Processes imported copper concentrate into LME Grade A copper cathode with annual capacity of 450,000 tonnes.",
    "registeredId": "fac-002",
    "idScheme": {
      "type": [
        "IdentifierScheme"
      ],
      "id": "https://facility-register.example.com",
      "name": "UNTP Sample Facility Register"
    },
    "countryOfOperation": {
      "countryCode": "JP",
      "countryName": "Japan"
    },
    "processCategory": [
      {
        "code": "41521",
        "name": "Unwrought copper",
        "definition": "Copper, unrefined; copper anodes for electrolytic refining; refined copper and copper alloys, unwrought.",
        "schemeId": "https://unstats.un.org/unsd/classifications/Econ/cpc/",
        "schemeName": "UN Central Product Classification (CPC)"
      }
    ],
    "relatedParty": [
      {
        "role": "owner",
        "party": {
          "type": [
            "Party"
          ],
          "id": "did:web:sample-refinery.example.com",
          "name": "Sample Copper Refinery Co. Ltd",
          "description": "Japanese copper smelting and refining company operating one of the largest copper smelters in Asia-Pacific.",
          "registeredId": "REF-001",
          "idScheme": {
            "type": [
              "IdentifierScheme"
            ],
            "id": "https://www.sample-register.example.com",
            "name": "Japan Corporate Number (Houjin Bangou)"
          },
          "registrationCountry": {
            "countryCode": "JP",
            "countryName": "Japan"
          },
          "partyAddress": {
            "streetAddress": "3-1 Sample, Usuki",
            "postalCode": "879-2201",
            "addressLocality": "Oita",
            "addressRegion": "Oita Prefecture",
            "addressCountry": {
              "countryCode": "JP",
              "countryName": "Japan"
            }
          },
          "organisationWebsite": "https://sample-refinery.example.com",
          "industryCategory": [
            {
              "code": "41521",
              "name": "Unwrought copper",
              "definition": "Copper, unrefined; copper anodes for electrolytic refining; refined copper and copper alloys, unwrought.",
              "schemeId": "https://unstats.un.org/unsd/classifications/Econ/cpc/",
              "schemeName": "UN Central Product Classification (CPC)"
            }
          ]
        }
      }
    ],
    "relatedDocument": [
      {
        "linkURL": "https://credentials.sample-cab.example.com/dcc/smelter-002",
        "linkName": "Coppermark Certification — Sample Copper Refinery",
        "mediaType": "application/ld+json",
        "linkType": "https://test.uncefact.org/vocabulary/linkTypes/dcc"
      }
    ],
    "facilityAlsoKnownAs": [
      {
        "type": [
          "Facility"
        ],
        "id": "https://prtr.example.go.jp/facilities/JP-44-SM-0021",
        "name": "Sample Copper Refinery",
        "registeredId": "JP-44-SM-0021",
        "idScheme": {
          "type": [
            "IdentifierScheme"
          ],
          "id": "https://prtr.example.go.jp",
          "name": "Japan PRTR Facility Register"
        }
      }
    ],
    "locationInformation": {
      "plusCode": "https://plus.codes/8Q7Q5G22+22",
      "geoLocation": {
        "latitude": 33.25,
        "longitude": 131.88
      },
      "geoBoundary": [
        {
          "latitude": 33.24,
          "longitude": 131.87
        },
        {
          "latitude": 33.26,
          "longitude": 131.89
        }
      ]
    },
    "address": {
      "streetAddress": "3-1 Sample, Usuki",
      "postalCode": "879-2201",
      "addressLocality": "Oita",
      "addressRegion": "Oita Prefecture",
      "addressCountry": {
        "countryCode": "JP",
        "countryName": "Japan"
      }
    },
    "materialUsage": {
      "applicablePeriod": {
        "startDate": "2024-01-01",
        "endDate": "2024-12-31",
        "periodInformation": "Calendar year 2024 reporting period."
      },
      "materialConsumed": [
        {
          "name": "Copper concentrate",
          "originCountry": {
            "countryCode": "ZM",
            "countryName": "Zambia"
          },
          "materialType": {
            "code": "14110",
            "name": "Copper ores and concentrates",
            "definition": "Copper ores and concentrates obtained from mining operations.",
            "schemeId": "https://unstats.un.org/unsd/classifications/Econ/cpc/",
            "schemeName": "UN Central Product Classification (CPC)"
          },
          "massFraction": 0.85,
          "mass": {
            "value": 420000000,
            "unit": "KGM"
          },
          "recycledMassFraction": 0,
          "hazardous": false
        },
        {
          "name": "Coke (reducing agent)",
          "originCountry": {
            "countryCode": "AU",
            "countryName": "Australia"
          },
          "materialType": {
            "code": "33100",
            "name": "Coke and semi-coke",
            "definition": "Coke and semi-coke of coal, of lignite or of peat; retort carbon.",
            "schemeId": "https://unstats.un.org/unsd/classifications/Econ/cpc/",
            "schemeName": "UN Central Product Classification (CPC)"
          },
          "massFraction": 0.1,
          "mass": {
            "value": 50000000,
            "unit": "KGM"
          },
          "recycledMassFraction": 0,
          "hazardous": false
        },
        {
          "name": "Silica flux",
          "originCountry": {
            "countryCode": "JP",
            "countryName": "Japan"
          },
          "materialType": {
            "code": "16120",
            "name": "Quartz and quartzite",
            "definition": "Natural sands, quartz and quartzite.",
            "schemeId": "https://unstats.un.org/unsd/classifications/Econ/cpc/",
            "schemeName": "UN Central Product Classification (CPC)"
          },
          "massFraction": 0.05,
          "mass": {
            "value": 25000000,
            "unit": "KGM"
          },
          "recycledMassFraction": 0,
          "hazardous": false
        }
      ]
    },
    "performanceClaim": [
      {
        "type": [
          "Claim"
        ],
        "id": "https://sample-refinery.example.com/claims/ghg-2024",
        "name": "GHG Emissions — Scope 1",
        "description": "Annual Scope 1 greenhouse gas emissions from the Sample Copper Refinery for the 2024 reporting year.",
        "referenceCriteria": [
          {
            "type": [
              "Criterion"
            ],
            "id": "https://sample-scheme.coppermark.org/criteria/ghg-management/v3",
            "name": "GHG Emissions Management (Coppermark RRA Criterion 26)",
            "conformityTopic": [
              {
                "type": [
                  "ConformityTopic"
                ],
                "id": "https://vocabulary.uncefact.org/conformity-topic/greenhouse-gas-emissions",
                "name": "Greenhouse Gas Emissions",
                "definition": "Assessment of direct and indirect greenhouse gas emissions across scopes 1, 2, and 3, including measurement, reporting, and reduction targets aligned with climate science."
              }
            ]
          }
        ],
        "claimDate": "2025-03-01",
        "applicablePeriod": {
          "startDate": "2024-01-01",
          "endDate": "2024-12-31",
          "periodInformation": "Calendar year 2024 reporting period."
        },
        "claimedPerformance": [
          {
            "metric": {
              "type": [
                "PerformanceMetric"
              ],
              "id": "https://vocabulary.uncefact.org/performance-metric/scope-1-ghg-emissions",
              "name": "Scope 1 GHG Emissions"
            },
            "measure": {
              "value": 120000,
              "unit": "TNE"
            }
          }
        ],
        "conformityTopic": [
          {
            "type": [
              "ConformityTopic"
            ],
            "id": "https://vocabulary.uncefact.org/conformity-topic/greenhouse-gas-emissions",
            "name": "Greenhouse Gas Emissions",
            "definition": "Assessment of direct and indirect greenhouse gas emissions across scopes 1, 2, and 3, including measurement, reporting, and reduction targets aligned with climate science."
          }
        ]
      },
      {
        "type": [
          "Claim"
        ],
        "id": "https://sample-refinery.example.com/claims/so2-2024",
        "name": "SO2 Emissions",
        "description": "Annual sulphur dioxide emissions from smelting operations at Sample for the 2024 reporting year.",
        "referenceCriteria": [
          {
            "type": [
              "Criterion"
            ],
            "id": "https://sample-scheme.coppermark.org/criteria/air-emissions-control/v3",
            "name": "Air Emissions Control (Coppermark RRA Criterion 28)",
            "conformityTopic": [
              {
                "type": [
                  "ConformityTopic"
                ],
                "id": "https://vocabulary.uncefact.org/conformity-topic/air-quality-management",
                "name": "Air Quality Management",
                "definition": "Management and reduction of air pollutant emissions, including particulate matter, volatile organic compounds, and other harmful substances affecting air quality."
              }
            ]
          }
        ],
        "claimDate": "2025-03-01",
        "applicablePeriod": {
          "startDate": "2024-01-01",
          "endDate": "2024-12-31",
          "periodInformation": "Calendar year 2024 reporting period."
        },
        "claimedPerformance": [
          {
            "metric": {
              "type": [
                "PerformanceMetric"
              ],
              "id": "https://vocabulary.uncefact.org/performance-metric/sox-emissions",
              "name": "SOx Emissions"
            },
            "measure": {
              "value": 3200,
              "unit": "TNE"
            }
          }
        ],
        "conformityTopic": [
          {
            "type": [
              "ConformityTopic"
            ],
            "id": "https://vocabulary.uncefact.org/conformity-topic/air-quality-management",
            "name": "Air Quality Management",
            "definition": "Management and reduction of air pollutant emissions, including particulate matter, volatile organic compounds, and other harmful substances affecting air quality."
          }
        ]
      },
      {
        "type": [
          "Claim"
        ],
        "id": "https://sample-refinery.example.com/claims/recycled-2024",
        "name": "Recycled Content",
        "description": "Percentage of recycled copper content in cathode output at Sample for 2024.",
        "referenceCriteria": [
          {
            "type": [
              "Criterion"
            ],
            "id": "https://sample-scheme.coppermark.org/criteria/recycled-feedstock/v3",
            "name": "Recycled Feedstock Management (Coppermark RRA Criterion 31)",
            "conformityTopic": [
              {
                "type": [
                  "ConformityTopic"
                ],
                "id": "https://vocabulary.uncefact.org/conformity-topic/recycled-material-integration",
                "name": "Recycled Material Integration",
                "definition": "Incorporation of recycled and reclaimed materials into products and processes, promoting circular material flows and reducing demand for virgin resources."
              }
            ]
          }
        ],
        "claimDate": "2025-03-01",
        "applicablePeriod": {
          "startDate": "2024-01-01",
          "endDate": "2024-12-31",
          "periodInformation": "Calendar year 2024 reporting period."
        },
        "claimedPerformance": [
          {
            "metric": {
              "type": [
                "PerformanceMetric"
              ],
              "id": "https://vocabulary.uncefact.org/performance-metric/recycled-content-percentage",
              "name": "Recycled Content Percentage"
            },
            "measure": {
              "value": 12,
              "unit": "P1"
            }
          }
        ],
        "conformityTopic": [
          {
            "type": [
              "ConformityTopic"
            ],
            "id": "https://vocabulary.uncefact.org/conformity-topic/recycled-material-integration",
            "name": "Recycled Material Integration",
            "definition": "Incorporation of recycled and reclaimed materials into products and processes, promoting circular material flows and reducing demand for virgin resources."
          }
        ]
      }
    ]
  }
}
